Alco-Sensor VXL with Slip Printer for DOT Testing SKU: 225
Alco-Sensor VXL with Slip Printer
The Alco-Sensor VXL with Slip Printer offers a fast testing protocol and is ideal for workplace testing programs that are stationary. Not considered to be a portable system.
Approved by the U.S. DOT as an Evidential Breath Testing device
Evidential accuracy exceeds +/- .005 at .100 BrAC
Intuitive menus prompt the operator through the DOT testing sequence, greatly reducing operator errors
Data Lite software version offers a fast testing protocol, eliminating unnecessary data entry and taking the operator directly to the test procedure
Automatic breath sampling ensures that each subject delivers an adequate breath sample, and then samples the breath at the optimum moment towards the end of the subjects exhalation
A manual breath sampling feature allows the operator to manually capture a breath sample from a subject with breathing difficulties or is being uncooperative
Automatically initiates a :15 wait period following a positive screening test of .02
Automatically initiates a confirmation test following the :15 wait period
Store and print thousands of test from the device’s internal memory
Right or Left handed operation makes testing fast and easy
Operates independently of the printer, allowing the operator to test the subject without being tethered to the printer
Docking station provides secure connection to the Slip Printer
Slip printer prints results directly onto the Alcohol Test Form, eliminating the need for printer paper and tamper tape
Optional Barometer interprets the value of alcohol gas tanks when performing Accuracy Checks and Calibration Adjustments. The barometer eliminates the need for a separate device such as the True-Cal II or an elevation chart when performing Accuracy Checks and Calibration Adjustments, and offers a higher degree of accuracy when using Alcohol Gas Tank calibration standards.
Alco-Sensor VXL Product Specs | |
Specs | |
Sensor type | Electrochemical oxidation (fuel cell) |
Range of Measurement | 0.00 – 0.440 BrAC |
Accuracy and Precision | US DOT approved for evidential use |
Breath sampling | Automatic with manual override |
Response time | 3 – 5 seconds for negative results, 5 10 seconds for positive results |
Power requirement | 4, AA batteries (included) |
Test mode | Direct |
Calibration | Microprocessor controlled, using gas or simulator |
Memory | Thousands of tests |
Print capability | Yes, with docking station and serial printer |
Computer capability | Yes, with docking station and optional Accelerator software |
Temperature range | -5 degrees C to 50 degrees C |
Size | 7 x 3 x 2 1/8, 12 oz |
Warranty | Two years, parts and labor |
Đánh giá