Fixed Mount FLIR EST™ Thermal Screening Solutions A500-EST, 42° Lens
[button link=”https://drive.google.com/file/d/1g8um5GfGeVZ6Tu8gFfoEjrun75qzwlyX/view?usp=sharing” target=”_blank” color=”default” shape=”rounded” size=”small” align=”left”]CATALOG[/button]
The FLIR A500-EST is a non-contact screening tool that can serve as a first line of defense against potential health risks. This FLIR EST™ thermal screening solution detects and visualizes heat to quickly identify individuals with an elevated skin temperature. With a 464 × 348 pixel thermal detector and on-camera FLIR Screen-EST™ Mode, the A500-EST can be deployed as a single, standalone screening station or in a network. Compatibility with industry standards such as Modbus TCP, MQTT, RESTful API for data transfer and RTSP for video makes third-party integration easy. The camera can be connected to most Video Management Systems and is compatible with FLIR Screen-EST™ Desktop software.
-
EASY SET-UP AND OPERATION
Integrates easily into web services with RESTful API over XML or JSON; offers standard EtherNet and Wi-Fi connectivity.
-
FAST, ACCURATE SCREENING
Optimal screening accuracy with automatic ambient drift compensation; support for external black body compensation if desired.
-
MAINTAIN SAFETY AND PRIVACY
On-camera FLIR Screen-EST Mode does not store images or personal information and allows for social distancing in screening setups.
SPECIFICATIONS | |
OVERVIEW
|
|
Accuracy [Drift] in Screen-EST Mode | ±0.3°C (±0.5°F) |
Alarm Functions | On any selected measurement function, digital in, internal camera temperature |
Alarm Output | Digital out, email (SMTP) (push), EtherNet/IP (pull), file transfer (FTP) (push), Modbus TCP master write (push), Modbus TCP slave (pull), MQTT (push), Query over RESTful API (pull), store image or video |
Base Mounting | 4× M4 on 4 sides |
Contrast Enhancement | FSX / Histogram equalization (IR only) |
Field of view (FOV) | 42° × 32° |
FLIR Screen-EST Mode | Yes |
Housing material | Aluminium |
IR Resolution | 464 × 348 |
Multi-Streaming | Yes |
Object Temperature Range | 15°C to 45°C (59°F to 113°F); camera provides contrast from -20°C to 120°C (-4°F to 248°F) but will not provide temperature information |
Size (L x W x H) | 123 × 77 × 77 mm (4.84 × 3.03 × 3.03 in) |
Warranty | http://www.flir.com/warranty/ |
Web interface | Yes |
Weight | 0.82 kg (1.8 lb), camera only |
CONNECTIONS & COMMUNICATIONS
|
|
Digital I/O connector type | M12 12-pin A-coded, Male (shared with external power) |
Digital I/O isolation voltage | 500 VRMS |
Digital input purpose | NUC, NUC disable, alarm, update screening reference sample |
Digital Inputs | 2x opto-isolated, Vin(low)= 0–1.5 V, Vin(high)= 3–25 V |
Digital Output Purpose | As a function of alarm, output to external device (e.g. when screening alarm is triggered); fault (NC) |
Digital Outputs | 3x opto-isolated, 0–48 V DC, max. 350 mA; solid-state opto relay; 1x dedicated as fault output (NC) |
Ethernet | For control, result, image, and power |
Ethernet Communication | TCP/IP socket-based FLIR proprietary |
Ethernet Connector Type | M12 8-pin X-coded, female; RP-SMA, female |
Ethernet Interface | Wired, Wi-Fi |
Ethernet Power | Power over Ethernet, PoE IEEE 802.3af class 3 |
Ethernet Protocols | EtherNet/IP, IEEE 1588, Modbus TCP Master, Modbus TCP Slave, MQTT, SNMP; TCP, UDP, SNTP, RTSP, RTP, HTTP, HTTPS, ICMP, IGMP, sftp (server), FTP (client), SMTP, DHCP, MDNS (Bonjour), uPnP |
Ethernet Standard | IEEE 802.3 |
Ethernet Type | 1000 Mbps |
Multicast | Yes |
Unicast | Yes |
WiFi | Yes. RP-SMA, female connector |
ENVIRONMENTAL
|
|
Atmospheric transmission correction | Based on inputs of distance, atmospheric temperature, and relative humidity |
EMC | ETSI EN 301 489-1 (radio), ETSI EN 301 489-17 (radio), EN 61000-4-8 (magnetic field), FCC 47 CFR Part 15 Class B (emission US), ISO 13766-1 (EMC – Earth-moving and building construction machinery), EN ISO 14982 (EMC – Agricultural and forestry machinery) |
Emissivity Correction | Variable from 0.01 to 1.0 |
Encapsulation | IEC 60529, IP 54, IP66 with accessory |
Humidity (Operating and Storage) | IEC 60068-2-30/24 hours, 95% relative humidity, 25°C–40°C (77°F–104°F)/2 cycles |
Lens Transmission Correction | Automatic, based on signals from internal sensors |
Measurement Frequency | Up to 10 Hz |
Operating Temperature Range | -20°C to 50°C (-4°F to 122°F); cooling plate needed for temperatures above 40°C (104°F) |
Radio Spectrum | FCC 47 CFR Part 15 Class C (2.4 GHz band US), FCC 47 CFR Part 15 Class E (5 GHz band US), RSS-247 (2.4 GHz and 5 GHz band Canada), ETSI EN 300 328 V2.1.1 (2.4 GHz band EU), ETSI EN 301 893 V2.1.1 (5 GHz band EU) |
Schedule Response | sftp (image), SMTP (image and/or measurement data/result) |
Shock | IEC 60068-2-27, 25 g |
Tripod Mounting | UNC ¼″-20 on 2 sides |
Vibration | IEC 60068-2-6, 0.15 mm at 10–58 Hz and 2 g at 58–500 Hz, sinusoidal; IEC 61373 Cat 1 (Railway) |
FILE STORAGE & DATA TRANSFER
|
|
Video Storage | Up to 10 H.264 videos stored as a function of alarm; 5 sec before or after alarm |
IMAGING & OPTICAL
|
|
Camera f-number | 1.1 |
Detector Type and Pitch | Uncooled microbolometer, 17 µm |
Focal Length | 10 mm (0.39 in) |
Focus | One-shot contrast, motorized, and manual |
Image Frequency | 30 Hz |
Lens | 42° |
Lens Identification | Automatic |
Overlay | With / Without |
Radiometric IR video streaming | RTSP protocol |
Readout | For measurement results: EtherNet/IP (pull); Modbus TCP master (push); Modbus TCP slave (pull); MQTT (push); Query over REST API (pull): measurements and still image (radiometric JPEG, visual 640 × 480, visual 1280 × 960) read access only; web interface |
Spatial resolution (IFOV) | 1.66 mrad/pixel |
Spectral Range | 7.5–14 µm |
Streaming Resolution | RTSP video streaming (source 0) – 640 × 480 pixels; RTSP video streaming (source 1) – 1280 × 960; radiometric streaming: 640 × 480 pixels |
Video Streaming | RTSP protocol |
Visible Camera | Included |
MEASUREMENT & ANALYSIS
|
|
Automatic hot & cold detection | Max/min temperature value and position shown within box |
External Optics & Windows Correction | Based on input of optics/window transmission and temperature |
Measurement Corrections | Global object parameters, local parameters per analyze function, external blackbody correction |
Measurement Presets | Yes |
Reflected apparent temperature correction | Based on input of reflected temperature |
OTHER
|
|
Thermal Sensitivity_NETD [typical] | <30 mK @ 30°C (86°F) |
POWER
|
|
External Power Operation | 24/48 V DC 8 W max |
External Voltage | Allowed range 18–56 V DC |
Power Connection | M12 12-pin A-coded, male (shared with Digital I/O) |
Power Consumption | 7.5 W at 24 V DC typical/7.8 W at 48 V DC typical/8.1 W at 48 V PoE typical |
RADIOMETRY
|
|
Image Source | Visual / IR / MSX |
SHIPPING INFORMATION
|
|
Packaging | Infrared camera with lens, Ethernet cable M12 to RJ45F (0.3 m/0.98 ft), printed documentation including login for web interface |
STORAGE MEDIA
|
|
Image Storage | Up to 100 FLIR radiometric JPEGs, stored as a function of alarm, scheduling, or user interaction (camera web) |
Đánh giá