Radiation Monitor PM5000B-05
Radiation Portal Monitors (RPMs) of PM5000B Series are highly sensitive fixed installation systems designed to automatically detect illicit trafficking of radioactive materials.
Application: airports, seaports, railway stations, customs and border checkpoints, nuclear plants and other facilities of the nuclear industry, nuclear waste disposal and storage sites, scrap metal industry, governmental offices, banks and post offices.
Operation Principle
RPMs have modular design and may have one-pillar or two-pillar configurations, adaptable height and width according to customer requirements. Monitors can be equipped with video monitoring system.
Key Features
High sensitivity
Advanced data processing algorithms
Modular design
Easy-in-use
Audible and light alarms
Indoor and outdoor installations
Reliable, automatic, 24/7 operation
PC connection through the Ethernet port
Video monitoring system (option)
Integration into a nuclear protection network controlled by a central PC (option) with further integration into higher level networks controlled by an Expert Center (option)
Modifications
РМ5000В-01 – two-pillar gamma monitor with 4 gamma radiation detector modules;
РМ5000В-05 – two-pillar gamma monitor with 2 gamma radiation detector modules;
РМ5000В-09 – two-pillar gamma-neutron monitor with 2 gamma-neutron radiation detector modules on 10B / ZnS (Ag) basis;
РМ5000В-10 – two-pillar gamma-neutron monitor with 4 gamma and 4 neutron radiation detector modules on 10B / ZnS (Ag) basis;
РМ5000В-13 – two-pillar neutron monitor with 2 neutron detector modules on 10B / ZnS (Ag) basis;
РМ5000В-14 – two-pillar neutron monitor with 4 neutron detector modules on 10B / ZnS (Ag) basis;
РМ5000В-16 – two-pillar gamma monitor which consists of 8 gamma radiation detector modules;
Monitored objects:
Cars
Pedestrians
Luggage
Application
Access ControlIllicit Trafficking of Nuclear and Radioactive MaterialsInspection of Raw Materials, Waste & GoodsInspection of Raw Materials, Waste & GoodsRadiation Security of Public Events & Sites
Standards Compliance
Designed to meet ANSI N42.35 – 2006 , ITRAP+10 (IAEA) requirements
Specifications | |
Type of registered radiation | gamma |
Energy range | 0.02 to 3.0 MeV |
Ingress protection | IP65 |
Number of detection units | 2 detectors |
Minimum detectable quantities of radioactive materials, control zone 3 x 2 m.: | |
241Am, MBq, (µCi); speed 5 km/h. | 0.62 (17) |
137Cs, MBq, (µCi); speed 5 km/h. | 0.065 (1.8) |
60Co, MBq, (µCi); speed 5 km/h. | 0.040 (1.1) |
238U, g; speed 5 km/h. | 460 |
235U, g; speed 5 km/h. | 32 |
239Pu,g; speed 5 km/h. | 0.9 |
57Co, MBq (µCi); speed 5 km/h. | 0.085 (2.3) |
133Ba, MBq (µCi); speed 5 km/h. | 0.040 (1.1) |
Minimum detectable quantities of radioactive materials, control zone 6 x 2 m.: | |
241Am, MBq, (µCi); speed 8 km/h. | 2.15 (58) |
137Cs, MBq, (µCi); speed 8 km/h. | 0.23 (6.2) |
60Co, MBq, (µCi); speed 8 km/h. | 0.145 (3.9) |
238U, g; speed 8 km/h. | 1800 |
235U, g; speed 8 km/h. | 110 |
239Pu,g; speed 8 km/h. | 3.2 |
57Co, MBq (µCi); speed 8 km/h. | 0.29 (7.8) |
133Ba, MBq (µCi); speed 8 km/h. | 0.145 (3.9) |
Power: | |
industrial AC network (115-230V range) | 47/63 Hz frequency |
built-in accumulator battery | 12 V DC (back-up). Accumulator battery enables continuous working of the monitor during 8 hours (no less than 8 hours). |
Power consumption: | |
no more then | 120 V•А. |
Mean time between failures | no less then 10000 hours |
Mean service lifetime | no less then 8 years |
Mean recovery time | no more then 60 min |
Weight | one gamma detector – 120 kg; control unit – 20 kg |
Operating temperature | -30 up to +50°C |
Humidity | up to 98 % at 40°C and lower, no moisture |
Atmospheric pressure | from 84 to 106.7 kPa |