LTF11 Integrated Magnetic Inductive Level Transmitter
Characteristics: It can work in different and extensive pressure. Good anti-jamming ability. More precise with permanent magnet. The sensor parts adopt the designation of integrated module: stable and reliable. High-resolution: as high as 5mm.
Profile
LTF11 Magnetic inductive transmitter integrates floating ball, sensor and transmitter. Compact structure and easy to install. In process of measurement, the ball built-in magnetic bundle unit shall move along a sensor made up of a serial of magnetic modules, under action of the magnetic unit, the magnetic module inside the sensor shall make counter point action, output a changed resistor signal, and then transfer the signal into a corresponding current output signal of 4~20mA.
Technical Parameter |
Measurement Range: 0~3000mm |
Rated Pressure: 0~1MPa If over 1MPa, please remark when ordering. |
Measurement Accuracy:±5mm |
Temperature Effect: ≤±0.1%FS/year |
Long-term Stability: ≤±0.2%FS/year |
Operating Voltage: 12Vdc~30Vdc |
Max. Power Loss: 1 W |
Output Current: 4~20mA |
Load Impedance: ≤750Ω (24Vdc) |
Insulation Impedance: ≥100MΩ (100Vdc) |
Wiring Mode: 5-core M12*1 aviation socket |
Ambient Condition: -40~80℃, ≤95%RH, avoid strong corrosive gas |
EMC Immunity |
IEC 61000-4-2:2001:Electrostatic Discharge Immunity Test Class 3 |
IEC 61000-4-3:2002: Radiated, Radio-frequency, Electromagnetic Field Immunity Test. Class 3 |
IEC 61000-4-4:2004: Electrical Fast Transient Immunity Test, Class 3 |
IEC 61000-4-5:2005: Surge Immunity Test, Class 3 |
Sản phẩm tương tự
Characteristics: It is polished, and the appearance is beautiful.
The magnetic unit material is NdFeB which is used in Space station, the magnetic structure is special,
so the magnetic beam is centered in the line plan, the strength can be sustained.
The output contact is with magnetic memory. Installation of insert mode, easy to maintain. Operation without electricity. Matching with photo-electric sign, apply to the condition of dusky light.
Profile
MN magnetic flap level meters adopt side mounting through a bypass pipe which is characterized by its easy installation, high stability and reliability or top mounting through a guide rod. The level meter is completely isolated between the inside and outsider cavity, and added a sealed flange at its bottom which can be opened easily to clean up dirt, impunity, etc.. One way level meters and meters adopting top mounting for its guide rod , equipped with a pressure hole in the top connected with atmosphere, are suitable for measuring level of medium at room temperature and pressure; Two-way level meters can be made with a certain operating pressure according to customers’ needs, and are suitable for measuring the liquid level of corrosive medium in places with high temperature, high humidity and high pressure. Level meters mainly consist of body of magnetic flat, display board of magnetic flat, floating ball, magnetic memory switch, ruler, etc.. In addition, an transmitter can be added according to customers’ needs.
Side mounted magnetic bundle unit through a bypass pipe is placed inside of the floating ball, while top mounted magnetic bundle unit is connected with a floating ball. When the floating ball moves over liquid level, the magnetic bundle unit shall move along a level relay made up of a serial of magnetic module. Under the action of the magnetic unit, the magnetic module inside the level sensor shall make a corresponding action, output a changed resistor signal, and then transfer the signal into a current output signal of 4~20mA. Meanwhile, the level can be observed directly through the quartz tube, and a magnetic switch shall conduct a related action at the corresponding point, making alarming action and control output.
Characteristics: It can work in different and extensive pressure. Good anti-jamming ability. More precise with permanent magnet. The sensor parts adopt the designation of integrated module: stable and reliable. High-resolution: as high as 5mm.
Profile: LTF21 Split-type Magnetic Inductive Level Transmitter’s measurement part and transmission part is connected by the cable, flexible for installation: suitable for narrow space or the circumstance where it can’t observe the values and wire after installation. In process of measurement, the ball built-in magnetic bundle unit shall move along a sensor made up of a serial of magnetic modules, under action of the magnetic unit, the magnetic module inside the sensor shall make counter point action, output a changed resistor signal, and then transfer the signal into a corresponding current output signal of 4~20mA.
Characteristics:
Transport by optional signal, away from lighting, strong magnetic and electrical’s interference;
The high molecular sieve is breathable but impermeable, it can avoid condensation effectively
The measurement interface is ceramic, so it can be able to bear corrosion and pollution.
The signal transports by fiber, its transmission distance can up to hundreds of kilometers.
The fiber’s interface is proprietary, so it is convenient wiring.
It uses ceramic capacitive measuring principle, the applications is convenient with high accuracy, the
performance is stable and reliable.
Profile:
LTL series of transmitter use dry ceramic sensors as measuring unit. When the sensor is put into the measured liquid, the level will give a pressure on the surface of the sensor’s membrane. According to the proportion principle to the liquid pressure and liquid level, it will produce a corresponding elastic displacement. Because the dielectric and the area between two plate is constant, the capacitance and the distance between the two level is in proportion, so from substrate electrode and diaphragm electrode it can detects the changing capacitance. When the capacitance is enlarged by fine-tuning circuit, it can export an accurate voltage signal. Then the outputted voltage signal will be transformed into corresponding light pulse signal and exported.
LTJ uses split installing, and connect by flange. The transmitter part with aluminum alloy shell is sealed fastening. The shell specially adds the high molecular sieve stomata, it is breathable but impermeable, it can prevent condensation and protect the transmitter. The airway cable connection would make sure the sensors is keeping fair with the atmospheric pressure. It is suitable for big range measurement.
We provide two types of probes for you to choose. The transmitter part transforms signal from sensors into corresponding light pulse signal, then exports it by fiber. The transmitter with aluminum alloy shell is sealed fastening, its protection class can up to IP65. The cable is made of ST plug fiber and it is convenient to install and debug. Our company specially selected a standard selection for customers, if you need some other options please tell us by special requirements.
The light pulse converter is used for transforming the input light pulse signal into corresponding electrical signal and then export it. It is the required components for light pulse level meter. LP light pulse converter applies high accuracy F/V conversion devices, it can transform the input light signal to corresponding signal with a range of 4~20mA and export it. DL fiber is single-mode fiber, the fiber comprehensively optimized the window’s performance of 1310nm and 1550nm. The dispersion on 1310nm window is the smallest. It comprehensively supports high capacity and low cost transmission of optical components.
Characteristics: It is polished, and the appearance is beautiful.
The magnetic unit material is NdFeB which is used in Space station, the magnetic structure is special,
so the magnetic beam is centered in the line plan, the strength can be sustained.
The output contact is with magnetic memory.Apply to the measurement of the level of the pressure container, corrosion resistance.
Profile
MN magnetic flap level meters adopt side mounting through a bypass pipe which is characterized by its easy installation, high stability and reliability or top mounting through a guide rod. The level meter is completely isolated between the inside and outsider cavity, and added a sealed flange at its bottom which can be opened easily to clean up dirt, impunity, etc.. One way level meters and meters adopting top mounting for its guide rod , equipped with a pressure hole in the top connected with atmosphere, are suitable for measuring level of medium at room temperature and pressure; Two-way level meters can be made with a certain operating pressure according to customers’ needs, and are suitable for measuring the liquid level of corrosive medium in places with high temperature, high humidity and high pressure. Level meters mainly consist of body of magnetic flat, display board of magnetic flat, floating ball, magnetic memory switch, ruler, etc.. In addition, an transmitter can be added according to customers’ needs.
Side mounted magnetic bundle unit through a bypass pipe is placed inside of the floating ball, while top mounted magnetic bundle unit is connected with a floating
The magnetic unit of the floating ball adopts a special magnetic group, which can still provide the required magnetic force for normal working of the transmitter even if used for a long period. Meanwhile, when the floating ball moves along a guide rod, the stronger linear magnetic field derived from the magnetic bundle unit of the floating ball, shall attract magnetic induction modules in the sensor one by one, thereby improving the accuracy rating and reducing the deviation of the transmitter.
ball. When the floating ball moves over liquid level, the magnetic bundle unit shall move along a level relay made up of a serial of magnetic module. Under the action of the magnetic unit, the magnetic module inside the level sensor shall make a corresponding action, output a changed resistor signal, and then transfer the signal into a current output signal of 4~20mA. Meanwhile, the level can be observed directly through the quartz tube, and a magnetic switch shall conduct a related action at the corresponding point, making alarming action and control output.
Main Technical Parameter
Body:
Measurement Range:0~3000mm(max.) (subject to actual goods)
Operating Pressure: Top mounting, one way, normal pressure
Two way: 1.0MPa, 2.5MPa, 4.0MPa or 6.3 MPa, etc..
Resolution Ratio: 5mm
Body Material: SUS304 or 316L
Connection Manner: Flange (subject to actual goods for special requirement)
Mounting Method: One way or two way flange(thread)side mounting
Ambient Condition: -20~80℃,≤95%RH (avoid strong corrosive gas)
Transmitter:
Measurement Range: 0~3000mm(Max.), optional
Measurement Accuracy: 5mm
Repeatability Deviation:±0.25%FS
Operating Voltage: 14~36Vdc
Maximum Power Loss: 5W
Output Signal:4~20Ma
Protective Tube for Sensor: 316L
Wiring Box: Aluminum
Load Resistance: <750Ω
Insulation Resistance: 100MΩ(500Vdc)
Ambient Condition: -20~60℃,≤95%RH,avoid strong corrosive gas
Protection Class:IP67
Magnetic Memory Switch
Contact Type: Standard Type: a couple of open&close passive contact output.
Current limiting output: with current limiting function and can be directly
input as PLC.
Active relay: extended contact output.
Contact Capacity: open/close contact: 1A /220Vac,1A /220Vdc
current limiting output:1A /220Vac,1A /220Vdc
active relay: 5A/24Vdc,1A/220Vac
Contact State: magnetic memory keeping switch
Insulation Resistor: ≥100MΩ (Under normal temperature)
Number of Action: 107 times
Enclosure Material: Alloy with oxidized surface
Ruler(Optional)
Overall Size: 2000(height)*13(width) mm
Figure Size: 5(height)*2(width)mm
Ruler Material: PVC adhesive plastics film
Đánh giá